Specifications

1) Hardware specifications

Model ECU1 Series
(Motor Power Supply Frequency)
ECU2 Series
(Motor Power Supply Frequency Pressure)
Variable motor power supply frequencies* 35/ 38/ 41/ 44/ 47/ 50/ 55/ 60 Hz
Variable pressure range - 0-2/ 7-9/ 14-16/ 16-18/ 18-20/ 21 MPa

* 50 Hz max. in 50 Hz areas.

Support for water-cooled hydraulic power supply units

[QF Series water-cooled hydraulic power supply units]

Type ECU1-010 ECU2-010 ECU1-020 ECU2-020 ECU1-040 ECU2-040 ECU1-070 ECU2-070
P/N 348-58216-xx * -01 -11 -02 -12 -03 -13 -04 -14
Applicable hydraulic power supply unit (water-cooled) QF-10B QF-20B QF-40B QF-70B
Motor capacitytd 5.5 kW 11 kW 22 kW 37 kW
Remote frequency setting yes yes yes yes yes yes yes yes
Remote hydraulic pressure setting no yes no yes no yes no yes
Size W600 x D250 x H520 mm W700 x D250 x H620 mm W600 x D250 x H520 mm
Weight Approx.25 kg Approx. 30 kg Approx. 50 kg Approx. 60 kg
Power supply capacity
(for existing motor power supply)
3-phase, 200 V, 8 kVA
Single-phase, 100 V, 1.5 kVA
3-phase, 200 V, 16 kVA
Single-phase, 100 V, 1.5 kVA
3-phase, 200 V, 32 kVA
Single-phase, 100 V, 1.5 kVA
3-phase, 200 V, 47 kVA
Single-phase, 100 V, 1.5 kVA

* P/N differs for retrofitting to existing product. Contact Shimadzu for further details.

Support for air-cooled hydraulic power supply units

[AF Series air-cooled hydraulic power supply units]

Type ECU1-A10 ECU2-A10 ECU1-A20 ECU2-A20
P/N 348-58216-xx * -07 -17 -08 -18
Applicable hydraulic power supply unit (air-cooled) AF-10B AF-20B
Motor capacity 5.5 kW 11 kW
Remote frequency setting yes yes yes yes
Remote hydraulic pressure setting no yes no yes
Size W250 x D250 x H520 mm
Weight Approx. 25 kg Approx. 30 kg
Power supply capacity (for existing motor power supply) 3-phase, 200 V, 8 kVA
Single-phase, 100 V, 1.5 kVA
3-phase, 200 V, 17 kVA
Single-phase, 100 V, 1.5 kVA

* P/N differs for retrofitting to existing product. Contact Shimadzu for further details.  

2) Optional software specifications

Software Windows software for 4830
OS Windows XP/ Windows Vista/ Windows 7
Applicable testing Motor frequency/ supply pressure setting/(manual) Permits settings for overall testing
Motor frequency/ supply pressure setting/(automatic) Fatigue/ endurance testing
(since wave, haversine wave, triangular wave, havertriangular wave)

* GLUON 4830 software is not supported. (Set supply pressure and motor frequency from 4830 servo contoller.)

Layout Diagram (Example)

* Appearance and specifications are subject to change without notice.

This page may contain references to products that are not available in your country.
Please contact us to check the availability of these products in your country.